ECtools checks existing RC buildings against EN 1998-3 or KANEPE 2022 and designs their strengthening with jackets or FRP. The building check requires ECtools Advanced or Advanced Non Linear.
1. Enable the building check
Open Building Check in the EC Design branch and tick Enable building check. Choose the assessment framework, EN 1998-3 (the default) or KANEPE 2022, from the list beside it. The window also holds:
- the load factors of the gravity and seismic check combinations, and the material safety factors γs, γc and γsw;
- Existing = ETABS group ECTOOLS-EXISTING only; rest designed as new, with normal load and material factors for the new members if selected;
- the redistribution of the support moments of existing beams;
- Jacket: automatic jackets for the failing members (thickness, materials, bars, stirrups and the beam jacket type: U under the slab, full rectangular, sides only or one of three L types);
- FRP: FRP strengthening of the failing beams and columns;
- the distribution of the shear of SD walls to their shear bands.
The button EN 1998-3 inputs... (or KANEPE 2022 inputs...) opens the inputs of the assessment: knowledge level, limit states and seismic action, method, existing members and material strengths.

2. Enter the existing reinforcement
During the design run, once the model is read, the window Existing Reinforcement asks for the as-built bars in the tabs Beam flexure, Column flexure, Beam shear, Column shear and Walls. Each row is matched to its element by the storey and the ETABS name (or the drawing name), not by its position, so tables pasted from a spreadsheet may be in any order. A row that matches no element is shown in red and is not used.
- Bending bars as 4Φ12, 4Φ12+2Φ16, or an area in cm². F or D can be typed instead of Φ.
- Shear bars as Φ10/200, Φ10/200(4) for four legs, or As/s.
- Walls: the boundary bars, the vertical and horizontal web bars and the hoops of the boundary elements.
- Optionally the local behaviour factor m of each beam and column.

The tables are saved in the work folder, so they need not be entered again. Copy and Paste exchange them with a spreadsheet.
3. Read the verdicts
The verdicts of the member ends are included in the design calculations issue. The check of every member end is also written to a text file in the work folder named after the framework (e.g. EN1998-3 members.txt); its path is given in the report. Inadequate members are shown red on the solution time bar-chart.
4. Strengthen with jackets
- Open an inadequate member in Nous (double click on the bar-chart). The section appears as <element>-<floor>, e.g. B100-STORY11.
- Add a jacket by coordinates or from the tab Jacket templates, and save the section in the work folder.
- Run the design again (Start, or Update report when only the work folder files changed). The jacketed sections are highlighted green in the data editing window; Assign jacketed sections to highlighted elements puts them in place.
- Optionally send them to the ETABS model with Update the ETABS model with the jacketed sections (API): every jacketed frame gets a section <section>_JACKET, so the model can be analysed again. Restore model (remove jackets) reverses this.
Alternative sections at the same location are named <element>-<floor>-New.sd; they take priority and are highlighted dark green. See Nous for the jacket tools.
5. Strengthen with FRP
With FRP ticked in the Building Check options, ECtools calculates the FRP needed by the failing beams and columns from the FRP properties for flexure and shear. The result appears in the report as the column Afrp and the FRP check. Where both Jacket and FRP are ticked, FRP is applied where its limits allow and a jacket is designed for the beams where they do not.
For the verification to EN 1998-3, columns can be wrapped with FRP in the 3-D viewer: select the columns, then Add FRP wrap from the right-click menu or from the panel Properties. The dialog takes the fibre (CFRP, AFRP or GFRP), the number of plies, the ply thickness, the corner radius and the FRP properties, as a continuous sheet or as strips.

A wrap can be updated, parked, re-instated or removed; nothing is deleted, the previous sections are kept in the subfolder Parked of the work folder. The wrap takes effect at the next design run, once its section has been assigned to the column with Assign jacketed sections to highlighted elements; the ETABS model is not changed, since a wrap does not change the stiffness of the column. The button Strengthening of the viewer colours the strengthened members by class.

A pushover analysis can follow: see Pushover analysis.